VERI-FRY® PRO and FS Tests
Gel-in-Tube Instant Chemistry (GiTIC™)


GiTIC™ TUBES

Four tests measure oil quality: 

TPM  Total Polar Materials (3-30%)
WET Water Emulsion Titratables (SOAPS from 5-60ppm)
FFA-75  Free Fatty Acids (0.01-0.7%)

FFA-350   

Free Fatty Acids (0.2-3.2%)

Each test is performed by introducing less than 5 grams of oil into vials containing patented gels. The vials are supplied 50 to a box with operating instructions. In the FFA and (ppm) WET tests, a chart is supplied that correlates the colorimeter's digital readout and the percentage of FFA and WET present in the oil. Customers can choose to have a custom curve made for the TPM. The vials' box (9.5"x4.5"x3.5") allows each vial to stand upright and can be used for holding and storing the self-documenting completed tests.

 

SP-830-LT
VERI-FRY PRO® SPECTROPHOTOMETERS

The VERI-FRY® PRO Spectrophotometer is a multi-wavelength colorimeter that passes a beam of light through an inserted vial and converts the absorbance units immediately into a digital readout of oil damage. The value is compared to a chart for the test to determine actual concentration. These meters give immediate readings with the press of a button. A production spectrophotometer reads all of the VERI-FRY® and many other tests. Not Currently Available

 

VF-CC
VERI-FRY® FS COLOR CARDS

A plastic color comparator card is available for the TPM test. Developed primarily for the restaurant industry, it allows for some degree of accuracy in determining oil quality, but lacks the precision of the digital meters. Should customers wish to upgrade to meters to enhance their quality control, the vials used with the TPM color card are also usable in the digital meters.

 

 WAR-ANA-12
WARMER (REACTOR) DRI-BATH

At their highest precision use, the VERI-FRY® tests are somewhat sensitive to temperature changes and the gel should be tested at 65°C ±2°C.  While any controlled heating method is acceptable, warmers are optional but recommended devices that can hold up to 12 individual vials at the ideal constant temperature. The vials stand upright and the number of wells allow for an ultra-fast assembly-line testing technique. A thermometer (not included), must be used to set the Warmer's operating temperature. The TPM test, used with the color card or meter, has only to be hot and clear, and usually does not require temperature stabilization. Not Currently Available

LAD-01
OIL LADLE

The TKT Teflon® ladle has been specially designed to take a sufficient sample amount for a single test without damaging or contaminating a frying oil sample. Its high resistance to heat transfer and 7" handle protect workers from burns.


REF-WET
REF-FFA-75
REF-FFA-350

REFERENCE SOLUTIONS

Reference solutions for the FFA and WET tests are available to ensure that the colorimeter maintains constant settings and reports consistent results. Each set contains five bottles, each with sufficient oil solution for four tests.

  • FFA-75 test solutions -Range: 0.01-0.7% FFA (oleic acid)
  • FFA-350 test solutions - Range: 0.2-3.2% FFA (oleic acid)
  • WET test solutions - 5, 10, 20, 35, 50 ppm (sodium oleate)
  • TPM calibration standards are available to ensure consistent meter readings.

The Total Polar Materials test, for official use, requires that calibrating oil samples first be examined through column chromatography to determine the true polar value correlation with the VERI-FRY® PRO meter readings. A custom-made TPM calibration chart must be constructed for each specific operation to remove the effects of any chemically interfering materials.

SYR-5
FTR-5

SYRINGES & FILTERS:


Filtering is generally necessary for testing used, abused or contaminated oils, to ensure maximum reliability of
PRO colorimeter readings. 

Filtering is required for samples of oil contaminated with sugars and phospholipids. Polypropylene syringes are 4" long and hold ~5ml of oil. The polypropylene filters remove particles down to 5 microns and offer simple, rapid filtering of heated liquid oils. Not Currently Available

CAL-TPM
CUSTOM-MADE CHARTS
Click to See a Custom Chart

Charts that compare typical oil degradation product concentration vs. spectrophotometer readings are included with WET and FFA vial boxes to graphically show FFA and WET contents determined in our spectrophotometer's digital read-out. The charts are printed from tests made with the Reference Solutions (supplied separately). In place of our laboratory reference solutions, samples of oil can be tested in our laboratory to ensure that the meter's readings will be calibrated to take account of factors unique to each user's situation, and this step is necessary for the TPM test, unless the user is relating the test results to food quality and not actual polar values. Developing a custom chart to correlate oil degradation product concentration in filtered oils to meter read-out ensures that an operator will have the best possible correlation to the quality of the oil being tested. 

Access the VERI-FRY® Price List   (pdf format*)  

 

* Requires Adobe® Reader®  version 6.0 or above for viewing and printing Adobe Portable Document Format - (pdf ).  Please click on the icon to download a free copy of Adobe® Reader®  

 